United Kingdom, November 24, 2026
Smith+Nephew, a global medical technology company, has announced the publication of new biomechanical research demonstrating the performance of its TENDON SEAM Rotator Cuff Repair System compared with conventional rotator cuff repair techniques. The study, published in the Muscles, Ligaments and Tendons Journal (MLTJ), evaluated the system’s mechanical performance in the repair of full-thickness supraspinatus tears, a type of injury involving the rotator cuff tendon in the shoulder. The findings showed that the TENDON SEAM construct achieved more than twice the strength reported for traditional knotted and knotless transosseous-equivalent (TOE) repair constructs and demonstrated a greater than tenfold reduction in gap formation during cyclic loading. The research also indicated that the construct maintained its integrity under loads estimated to occur during the tendon-healing period. These findings highlight the potential of the technology to improve mechanical stability during the early stages of recovery following rotator cuff surgery.
TENDON SEAM Demonstrates Improved Biomechanical Strength
The published research assessed the biomechanical performance of the TENDON SEAM technique using human cadaveric testing and compared the results with previously published biomechanical data for conventional knotted and knotless TOE repair constructs. The comparisons used similar testing protocols to evaluate relative performance. According to the findings announced by Smith+Nephew, the TENDON SEAM construct demonstrated more than twice the strength of the conventional repair approaches evaluated. The study also reported that the system maintained its structural integrity under a load of approximately 302 Newtons over 500 cycles, a loading condition estimated to represent forces that may be experienced during the healing period. Maintaining the stability of a repaired tendon is an important consideration in rotator cuff surgery because excessive movement or separation at the repair site can affect the mechanical environment during tissue recovery. The findings therefore provide encouraging biomechanical evidence for the system’s design. However, the research was conducted using cadaveric specimens and mechanical testing, rather than a clinical trial measuring patient recovery or long-term surgical outcomes.
More Than Tenfold Reduction in Tendon Gap Formation
One of the notable findings involved gap formation during cyclic loading, which measures the separation that can develop at a tendon repair site when repeated forces are applied. The TENDON SEAM construct demonstrated substantially less gap formation than the conventional TOE repair constructs included in the comparison. After 30 loading cycles at 180 Newtons, the reported gap measurement for TENDON SEAM was approximately 0.33 mm, compared with 3.74 mm for knotted TOE repair and 8.10 mm for knotless TOE repair. These results indicate a greater than tenfold reduction in gap formation relative to the conventional constructs evaluated. Limiting gap formation is relevant to rotator cuff repair because maintaining close contact between the tendon and its attachment site is an important mechanical consideration during healing. The company stated that the findings support the potential of the TENDON SEAM construct to provide improved stability and load distribution during early recovery. Nevertheless, reduced gap formation in laboratory testing does not independently establish improved tendon healing rates, reduced complications or better functional outcomes in patients. Clinical evidence will be needed to determine whether the biomechanical advantages translate into measurable benefits following surgery.
Anchor-and-Suture Design Supports Load Distribution
The TENDON SEAM Rotator Cuff Repair System uses multiple closely spaced anchors measuring 2 ร 10 mm, connected through a continuous stitch. Its design creates a seam of fixation positioned perpendicular to the direction of load, with the aim of distributing forces across the repaired tendon rather than concentrating them at individual fixation points. This load-sharing approach is intended to provide a stronger and more stable repair construct during the period when the tendon is recovering. Smith+Nephew recently acquired the TENDON SEAM System as part of its efforts to expand its shoulder repair and sports medicine portfolio. The company believes the technology could support surgeons in rotator cuff procedures by offering an alternative fixation approach. Patrick Connor, MD, Chief of The Sports Medicine Center at OrthoCarolina, commented on the construct’s strength and stability and its potential to support a more progressive rehabilitation approach. Ryan Majkrzak, Senior Vice President and General Manager of Global Sports Medicine at Smith+Nephew, also highlighted the company’s focus on advancing rotator cuff repair technologies.
The publication adds to the scientific evidence supporting innovation in orthopaedic sports medicine and tendon repair technologies. While the reported biomechanical results are promising, further clinical research will be important to establish how the system performs in real-world surgical practice and whether its mechanical characteristics translate into improved patient outcomes. The findings position TENDON SEAM as a notable development in rotator cuff repair technology, particularly in the areas of repair strength, load distribution and resistance to gap formation during repeated loading.
Source: Smith+Nephew press release